Section 5A

9/440 Resolver--based CNC/Drive System

5A-25

The remote I/O circuitry and connector are integral parts of the wiring
board in the 9/440 resolver--based system module. Figure 5A.11 shows the

remote I/O connector mounted on the 9/440 resolver--based control wiring

board.

Wire connections for the remote I/O communications are made through the

TB4 NODE ADAPT connector. Connect the wires for remote I/O as

shown in the following figure. Refer to your 1771 I/O documentation for

details on making remote I/O connections.

Figure 5A.11

Remote I/O Connector in System Module

9/440 Resolver--based System Module

Open Cover

TB4

RIO

2

SH

LD

RIO

1

Remote I/O

Plug

Cl

ea

r

Sh

ie

ld

Bl

ue

9/440 Resolver- based Control Remote I/O LED

Assuming you have:

made all necessary remote I/O communication connections on your
1771 I/O network

configured your remote I/O port for the remote I/O network in AMP

written PAL to set $RMON true during the first PAL foreground
execution, and to handle input and output words ($RMI1 -- $RMI8

inputs to PAL and $RMO1 -- $RMO8 outputs from PAL.)

5A.4.2

9/440 Resolver- based

Control Remote I/O

Connection