I/O Interface

Section 10A

10A-49

You can place several 1746I modules with 1746 I/O chassis in the 9/Series
fiber-optic ring. Each 1746 I/O chassis must contain its own 1746I module

(daisy chaining racks together using one 1746I module is not allowed).

The number of I/O points/chassis is limited to the number of ASRN chips

supported by the 9/Series fiber--optic ring. Use page 10B-10 to calculate

how many ASRN chips are required for each I/O chassis. A maximum of

16 chassis are allowed on the 9/Series fiber-optic I/O ring.

1746I adapter module

1746 Series B I/O Chassis

Three different fully equipped 1746 I/O chassis are available for the

9/Series I/O ring. These chassis contain the following I/O devices:

Table 10A.AJ

Standard 9/Series 1746 I/O Catalogs

Catalog Number

8500-S115

Catalog Number

8500-S24

Catalog Number

8500-SANL

(1) 1746-A4

4 Slot Chassis

(1) 1746-A4

4 Slot Chassis

(1) 1746-A4

4 Slot Chassis

(1) 1746-P1

115/230V ac Power Supply

(1) 1746-P1

115/230V ac Power Supply

(1) 1746-P1

115/230V ac Power Supply

(1) 8500-1746I

I/O Ring Interface Adapter

Module

(1) 8500-1746I

I/O Ring Interface Adapter

Module

(1) 8500-1746I

I/O Ring Interface Adapter

Module

(2) 1746-IA16

16 point 115V ac Input

Module

(2) 1746-IB16

16 point 24V dc Input Module

(1) 1746-NIO4V

Analog Input Module

(1) 1746-OA16

16 point 115V ac Output

Module

(1) 1746-OW16

16 point 24V dc Output

Module

(1) 1746-N2

2 Empty Slot Covers

(1) set fiber optic

connectors

for connection to I/O ring

(1) set fiber optic

connectors

for connection to I/O ring

(1) set fiber optic

connectors

For connection to I/O ring

Total I/O

32 115V ac Inputs

16 115V ac Outputs

3 ASRN chips

Total I/O

32 24V dc Inputs

16 24V dc Outputs

3 ASRN chips

Total I/O

2 analog input chnls.

2 analog output chnls

6 ASRN chips