Section 4B

Connecting the 3-axis Servo Module

4B-50

Figure 4B.40

Typical Wiring of a Touch Probe Configured for Rising Edge Trigger

11309-I

5
4
3
2
1

Servo Module

26LS32

470 ohm

5V common

1000 ohm

+5 V dc

6

BAT/TP

TB1

Probe Contact

Wiring a Probe for Falling Edge Configuration

Figure 4B.41 shows a typical wiring diagram compatible with most probe

designs configured to trigger on the falling edge of the probe signal.

Figure 4B.41

Typical Wiring of a Touch Probe Configured for Falling Edge Trigger

5
4
3
2
1

Servo Module

26LS32

470 ohm

5V common

1000 ohm

+5 V dc

6

BAT/TP

TB1

1000 ohm

pull down resistor

(customer supplied)

Probe Contact

Wiring a Probe to Multiple Servo Cards

Systems with more than one servo module should have their touch probe

connections tied together in parallel. This allows the position to be latched

on all servo modules at the same time with the same input. Only one

power connection needs to be made (with pull up or down resistor). The

other probe connections should be made in parallel on all servo cards.