background image

Section 5B

9/440HR CNC/Drive System

5B-38

9/440HR CNC/Drive has 4 LEDs on the system module and one LED on
each axis module in the system. The LEDs operate as follows.

System Module LEDs

The system module has 4 LEDs. They are:

LED

Indicates

XILINX

Under normal operation this LED is on. If it

turns off while the system module is under

power it indicates a XILINX hardware fault.

Contact your local Allen--Bradley Service.

WATCHDOG

Under normal operation this LED is on. If it

turns off while the system module is under

power it indicates the watchdog has timed out

and a processor failure has occurred. Contact

your local Allen-Bradley Service.

R--I/O

Only available on systems with remote I/O. This

LED illuminates when the remote I/O link is

communicating. See page 5B-27.

STATUS

This is identical to the Watchdog LED but is

visible through the system modules front cover.

9/440HR System Module

Open Cover

Press Cover

Release to Open

Wiring Board

WATCHDOG

XILINX

Status LED

R-I/O LED

(visible from under system

module in front of serial

port B)

Check your 9/Series CRT for any drive faults that may have occurred and

are displayed as an error.

5B.7

9/440HR LEDs