Section 11A

Connecting 1394 Digital Drive Systems

11A-4

Maximum Axis Speeds

Maximum axis speeds are limited by the CNC interface boards ability to

decode resolver feedback and convert it into encoder A quad B feedback.

The maximum motor RPM when set for 32768 counts/rev is 3000 RPM.

Actual final axis speed is based on gearing and lead screw pitch.

Exceeding this motor speed can result in feedback overflow on the CNC

interface board and a feedback error will be generated.

Connecting Resolver Feedback

Resolver feedback is wired directly from the motor mounted resolver to the

CNC wiring board found in the system module. This cable can be

purchased directly from Allen-Bradley (cat no 1326-CCU-xxx).

CNC Wiring Board

CNC Interface Board

System Module

Resolver Connectors

61

62

TB1

61

DROK

TB3

FB3

FB2

FB1

FB0

J4

63

6466

(cover removed)

Resolver Connectors

CNC Wiring Board

Advertising