Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 123

Advertising
background image

Section 3B

Power Distribution

3B-2

This section discusses the connections of the main power supply and the

operator panel power supply.

Connecting the Main Power Supply to AC Power Source

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

Important: In addition to supplying power to the operator panel power

supply, the main power supply also supplies power to the motherboard and

the CPU board. As shown in Figure 3B.2, the power cables for these

modules originate from the side of the main power supply.

Refer to Figure 3B.2 while performing these steps:

1.

Locate AC-IN, L1, L2, and PE on terminal block BT04.

2.

Connect the ac power source cable (C02) from the external ac power

source to AC-IN, L1, L2, and PE on BT04.

3.

Connect the chassis ground terminal to the cabinet’s grounding bus bar.

Important: The chassis ground terminal connects to the control chassis

and designated cable shields. Power supply common is AC coupled to

chassis ground. It is the users responsibility to determine if a direct

connection to cabinet ground bus is required.

3B.1

Connecting the PS2 Main

Power Supply

Advertising