Section 7C

Power Distribution and Wiring Guidelines

7C-4

electromagnetic noise. If there is no electric conductivity between the

metallic conduit and the frame or the cabinet, connect them using a

conductor.

Important: Run cables carrying weak signals inside metallic conduit

whenever possible. Do not use the metallic conduit as the grounding

connection for the frame or the cabinet. Use an exclusive conductor for

grounding.

Figure 7C.2

Cable Routing

Machine

connections

panel

Motor power

Feedback

AC power

AC power

Axis

drive

cabinet

Recommended

steel

dividers

9/230, 9/260, or

9/290

controller cabinet

Customer

AC

power

Application

power

distribution

panel

Axis signals

Drive command

Discrete I/O

Machine

cable

conduits

11238-I

Noise Suppressors

To prevent noise in the ac power line on the power receiving side

(controller side), connect a filter or transformer as shown in Figure 7C.3.