Section 3A

Primary 9/230 Components

3A-5

Table 3A.B

Connector TB2, TP, Terminal Assignments

Terminal

No.

Signal

Description

Signal Destination

1

+5V

Probe Power

Touch Probe

2

PRB_FIRE

Probe Fired Signal

1

Servo Module

3

TP_GRD

Touch Probe Common

Touch Probe

4

Shield

Probe Shield

connect at module

only

1

The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as defined

by the AMP parameter PROBE TRANSITION.

Refer to the 9/Series CNC 9/230,

9/260, and 9/290 AMP Reference Manual, publication 8520-6.4, for more

information.

Important: The touch probe connector supports only +5V probing device

applications.

The 9/230 can have two LEDs (DS4 is present only if you have purchased

the 9/230 remote I/O option). Figure 3A.1 shows the location of these

LEDs on the main board. Use them to determine the following:

Table 3A.C

LED Sequence at Power Up for the 9/230

LED

Status

Description

DS2

WDOG OK

ON

System is running.

WDOG OK

OFF

Watchdog timeout has occurred, or system did not

power-up properly

DS4

NA COMM

ACTIVE

ON

Active Link to PLC. This is the normal state when the

RIO channel is on and active.

ACTIVE

FLASHING

The remote I/O channel is on and active but the PLC is

currently in program mode.

OFF

Remote I/O channel is offline. The port is not being

used, not configured, or not attached to a remote I/O

scanner device.

3A.1.2

Reading LEDs