Section 3B

Power Distribution

3B-6

Connecting the Main Power Supply to the Portable

Operator Panel Interface Assembly Power Supply

You connect the Portable Operator Panel Interface Assembly power supply

directly to the main power supply. Refer to Figure 3B.2 and Figure 3B.4

when performing these steps:

1.

Use the ac power supply cable (C03) to connect terminals AUX-AC

L1 and L2 of terminal block BT04 on the main power supply to

terminals L1 and L2 of terminal block BT02 on the power supply for

the portable operator panel interface module.

2.

Connect the chassis ground terminal on the portable operator panel

interface assembly power supply to the cabinet’s grounding bus bar.

Figure 3B.4

Power Supply Connector on Portable Operator Panel Interface Assembly

G

ND
12V

G

ND

5V
G

ND

5V

G

ND

5V

AC

L2

L1

PE

L1

PE

L2

GND

5V

TO HPG

5V

5V

12V

GND

GND

GND

TO HPG

TO HPG

TO MTB panel