Section 15A

Troubleshooting The Control

15A-34

When the {FAST I/O} softkey is pressed on the Main Diagnostics Menu

screen, the Fast I/O screen appears. “FAST I/O” appears at the top to

identify the screen, along with the “SETUP MODE” message indicating

that the control is in setup diagnostics mode.

Figure 15A.15 shows an example of the Fast I/O screen.

Figure 15A.15

Fast I/O Diagnostics Screen

FAST I/O

SETUP MODE
ON =

CN17F

IN

01 03 05 07

OUT

09 11 13 15

The screen shows connector CN17F, which is the Fast I/O connector

number. It is followed by the four input terminals (01, 03, 05, and 07) and

the four output terminals (09, 11, 13, and 15).

If an input or output is “ON”, its terminal number appears in inverse video.

This is a real time display, and its response is limited only by delays in

screen updates.

Pressing the exit softkey (up arrow) at any time displays the Main

Diagnostics Menu screen.