Filtering power for a 9/440 system, Connect the power line filter to c55 as shown – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 875

Advertising
background image

Section 17

Installing 9/Series Hardware for CE Compliance

17-3

Filtering Power for a 9/440 System

To comply with CE guidelines you need to connect a power line filter to

cable C55. The type of filter you need is:

Product

Part Number

Manufacturer

Phone Number

Power Line Filter

MIF323-GS

Roxburgh Electronics LTD

Foxhills Industrial Park

Scuntharpe

South Humberside, DN158Q5

United Kingdom

011-44-017-242-81770

Connect the power line filter to C55 as shown:

Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C55

9/440

External 380/460V Three Phase

Drive Power

9/440 System Module

Power Terminal Block

Prepared by Customer

DC+

INT

COL

W1

W2

U

W

V

PE

9/440 Power Strip

Noise suppressor

AC Bulletin 100--A30N x 3 (surge protector required) or

DC Bulletin 100--A30NZ x 3

Bussman FRS--R--20A (min) 600 V AC

FRS-R-30A (max) 600V AC

or equivalent (qty 3)

Three-phase input

380-460V AC

Bulletin 100

Contactor Power

C

55

E-STOP Status Contactor

(customer supplied or internal 9/440 TB1 status)

LO

AD

LI

NE

Power

Line Filter

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

Miscellaneous

See Local Codes

(12Awg max)

Clamped by terminal screws

Line Drop Limitation