Table 9A.I shows the output specifications of the removable operator panel

interface power supply. For input specifications and fuse specifications

refer to page 4D-5.

Table 9A.I

Interface Assembly Power Supply Output Specifications

Item

Specifications

Remark

Outputs

5 V dc (3 terminals) 0.4 A/channel

For HPGs

12 V dc (1 terminal) 1.5 A

For MTB Panel I/O Module

5 V dc

For Keyboard I/O Module

12 V dc

For Monochrome CRT

Protection Function

Overcurrent protection

Connection

Terminal Block

Your removable operator panel connects to the 9/Series control through the
removable operator panel interface assembly you installed as discussed on

page 9A-15. The connection between removable operator panel and

interface assembly is made via a 10 ft (max length) cable. This cable is

provided with your removable operator panel.

Attach the removable operator panel cable between the interface assembly

connector CN5 and the 37--pin D--shell connector on the front of your

removable operator panel. You can attach or detach the operator panel at

any time. We do not recommend, however, disconnecting this panel while

in the middle of editing online or Patch AMP or while editing a part

program.