Section 10B

9/Series Adapter Modules for

1771 and 1746 I/O Devices

10B-6

Assign an address to the module using the dip switch S1 found on the side

of the 1746I module. Figure 10B.4 shows the location of the node address

switch assembly on the 1746I module.

Figure 10B.4

1746 I/O Ring Adapter Switch Assembly Locations

S1

1 2 3 4 5 6

ON

Other 9/Series I/O devices (such as an HPG or MTB panel) on the 9/Series

fiber-optic ring can have the same node address as the 1746I module.

However, devices of the same type (multiple 1746I modules) must each

have a unique node address. Each 1746 I/O ring adapter is assigned a

unique node address in the I/O assignment file of ODS (refer to your PAL

reference manual). This address corresponds to switch assembly S1 on the

1746I module.

Set switch assembly S1 to correspond to the node address as shown in

Table 10B.C.