Section 15A

Troubleshooting The Control

15A-12

If you have designed custom screens through PAL (PAL display pages),

you can not use the hotkey to jump to and from the search monitor utility

from these screens.

The search monitor can also be password protected to prevent unauthorized

access. Protecting the search monitor utility with password protection

disables not only the softkey access to the utility, but the hotkey access as

well. If however you password protect the System Suport softkey, access

to the search monitor utility is still available using the hotkey. Password

protecting System Suport only prevents softkey access to the search

monitor utility. Refer to your 9/Series Operation and Programming

manual for details on password protection.

This section defines the setup diagnostic functions available to assist with

integrating the control to the machine tool. The diagnostics can be run any

time the control is powered up and the fiber optic ring is correctly

connected.

The diagnostic functions are used to check and monitor all I/O devices. It

can also be used to monitor individual axis parameters such as following

error, torque, and others.

To access the control’s diagostic functions:

1.

Press the {SYSTEM SUPORT} softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

If the control determines (through password identification) that the

current user is allowed access, then the {MONITOR} softkey

appears on the second softkey level. If this softkey does not appear,

refer to the password and/or access control section of your operation

and programming manual.

2.

Press the {MONITOR} softkey.

(softkey level 2)

PRGRAM

MANAGE

AMP

DEVICE

SETUP

MONI-

TOR

TIME

PARTS

15A.3

Setup Diagnostics