4a.4 reading leds, System error led pattern – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 142

Advertising
background image

Section 4A

Primary 9/260 and 9/290 Components

4A-8

The green and red LEDs on the motherboard and the CPU board for 9/260

and 9/290 indicate the overall status of your system during power and

operation. Use Table 4A.B to read these LEDs when you power up the

system.

Table 4A.B

LED Sequence at Power Up for the 9/260 and 9/290

Motherboard LEDs

CPU Board

LED

Red

Green

Green

Status

OFF

OFF

OFF

CNC off- No power

ON

OFF

OFF

Power is on. Control begins diagnostics. If control does

not quickly change states, this indicates an error during

diagnostics. If cycling power does not clear the error,

then contact A-B System Support Services.

ON

ON

OFF

CNC is on and running diagnostics. If control does not

quickly change states, this indicates an error during

diagnostics. If cycling power does not clear the error,

then contact A-B System Support Services.

OFF

ON

OFF

Diagnostics completed. Check CRT for error messages.

If control does not quickly change states this indicates

an error. If cycling power does not clear the error, then

contact A-B System Support Services.

OFF

ON

ON

System is running.

System Error LED Pattern

If this LED pattern appears while the control is running, contact

Allen-Bradley Support Services:

Motherboard LEDs

CPU Board LED (for 9/260 and 9/290)

Red

Green

Green

Status

OFF

ON

OFF

Watchdog timeout has occurred.

4A.4

Reading LEDs

Advertising