3a.7.4 digital servo amplifiers – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 113

Advertising
background image

Section 3A

Primary 9/230 Components

3A-30

Two versions of the 9/230 digital are available which interface to the 8520
digital amplifier or the 1394 digital amplifier. Do not attempt to interface

an 8520 digital 9/230 to a 1394 drive or a 1394 digital 9/230 to an 8520

digital drive. These two systems are mutually exclusive.

Both the 1394 and 8520 digital servo amplifiers receive an “Axis enable”

signal and returns a “Drive OK” signal from/to the 9/230 digital CNC

provided certain system and motor tests are successful.

Important: The digital servo amplifier should be separated or isolated

from the processor module because of the electrical noise it generates.

Refer to page 7A-1 for unit mounting spacing and other noise prevention

techniques that will have to be followed when installing 8520 digital

amplifiers. Refer to your 1394 Amplifier documentation for details on

installing 1394 drive systems.

Figure 3A.21 shows the interface between the digital servo interface and

the servo amplifier.

Figure 3A.21

Digital Servo Amplifier Interface

9/230 Digital

J1

J2

J3

ANALOG OUT

Servo

Amplifier

CNA1 or

CNC1

(Axis 1)

CNA2 or

CNC2

(Axis 2)

CNA3 or

CNC3

(Axis 3)

Spindle

amplifier

Drive Signal

Axis enable

Status

Velocity signal (analog)

11089-I

Feedback (1394 only)

Important: The configuration of the digital servo module output ports

with the digital servo amplifier connectors will vary depending on the

AMP configuration of the system. Refer to the 9/Series CNC AMP

Reference Manual, publication 8520-6.4, for more information.