Control screen, Pc screen – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 761

Advertising
background image

Section 15B

Replacement Procedures

15B-5

6.

Press any key when you have connected the control to your personal

computer. After a few minutes the PC displays this screen:

Connection established.
Device is a 9/290 CNC
Downloading required system modules...

Module:Boot Directory Revision 1.0

Status: downloaded

Module:XLINX Data

Revision 1.0

Status: downloaded

Module:Main CPU Exec

Revision 1.0

Status: downloaded

Module:I/O CPU Exec

Revision 1.0

Status: downloading (81%)

If you have a 9/230 or 9/260 a similar screen appears that does not

include the last message about the I/O CPU. Also, the 9/230 downloads

a servo executive. If this screen does not appear, refer to the table at the

end of this section for a listing of status and error messages.

7.

Once the download is complete:

Informative Messages

Host Operations Complete.
Power Down Control.

Disconnect Serial Channel Then
Restart the Control.

Error Messages

Control Screen

Connection established.
Device is a 9/290 CNC

Downloading required system modules...

Module:

Boot Directory

Revision 1.0 Status: downloaded

Module:

XLINX Data

Revision 1.0 Status: downloaded

Module:

Main CPU Exec

Revision 1.0 Status: downloaded

Module:

I/O CPU Exec

Revision 1.0 Status: downloaded

Download complete.
The CNC system is now ready to use.

Power down the CNC.
Disconnect the RS-232 cable.

Then restart the CNC and check the updated system.

If there are problems, the update may be retried.

Retry update (y/n)?