I/O Interface
Section 10A
10A-45
Table 10A.AG lists the output specifications for the analog I/O.
Table 10A.AG
E- Series Analog I/O Output Specifications
Item
Specifications
Remark
Number of Output Points 1
Operating Voltage
Bipolar: -10 to +10 V dc
Unipolar: 0 to +10V dc
Range selected by switch
next to the node address
switch on the analog I/O
Resolution
12 bit binary
Load Drive Capability
Maximum 10 mA
No Sustained Oscillation
Maximum 1
m
F
Maximum
m
F
Response Rate
Less than 200
m
sec
Connection
Terminal Block
PAL Variable Values
Bipolar:
0 -- 2047 (0 to +10V dc)
2048 -- 4096 (--10 to 0 V dc)
Unipolar:
0 -- 4096 (0 to +10V dc)
The PAL variable name is
determined in your I/O
configuration using ODS.
Figure 10A.36 shows a typical analog I/O output device connection.