Section 10B

9/Series Adapter Modules for

1771 and 1746 I/O Devices

10B-3

Different types of I/O devices can have the same node address, but devices

of the same type must each have a unique node address. Each 1771 I/O

ring adapter is assigned a unique node address in the I/O assignment file of

ODS. This address corresponds to a switch setting on the device itself. Up

to 16 addresses are available. Figure 10B.2 shows the location of the node

address switch assembly on the 1771 I/O ring module.

Figure 10B.2

1771 I/O Ring Adapter Switch Assembly Locations

S1

S2

S3

O

PE

N

1
2

3

4
5
6

7

8

OFF

ON

11343-I

Important: Switch assemblies S1 and S2 indicate which slots in the I/O

chassis have modules installed and operating. Refer to the Allen-Bradley

1771 I/O Ring Adapter Module Product Data Sheet, publication

8500-4.5.1, for additional information on this module.

Set switch assembly S3 to correspond to the node address as shown in

Table 10B.B.

Important: Switch numbers 7 and 8 of switch assembly S3 are not used.

Their position should not be altered.

10B.1.2

1771 I/O Ring Adapter Node

Address Setting