Hand pulse generator, Figure 2b.20 hand pulse generator dimensions, Figure 2b.21 hand pulse generator dimensions – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 74
Advertising
![background image](/manuals/580751/74/background.png)
Section 2B
Mounting Dimensions
2B-17
Hand Pulse Generator
For detailed information on this component refer to page 9A-1.
Figure 2B.20
Hand Pulse Generator Dimensions
80 Ж
60 Ж
Front
Bottom
Side
119 (4.69)
Common terminal
+5 V dc terminal
Fiber optic connectors
Address switches
I/O ring fault indicator
48max.
(1.89)
50
(1.97)
28
(1.10)
4 Æ x 15 long,
three places, on
72 Æ bolt circle
60
(
j2.36)
46 max.
(1.81)
(3.15”)
(2.36”)
11082-I
mm
(in.)
The hand pulse generator weighs .58 kg (1.28 lb).
Figure 2B.21
Hand Pulse Generator Dimensions
gasket
mounting panel
4.8 (0.19)
Æ
, three places
holes 120 degrees apart
72 +.2
Æ
bolt circle
(2.83 +0.01)
62 +.8 (2.44 +.03)
Æ
clearance bore
11190-I
mm
(in.)
Advertising