Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 726

Advertising
background image

Section 15A

Troubleshooting The Control

15A-16

Figure 15A.3

High Density I/O Diagnostics Screen

HIGH DENSITY I/O

SETUP MODE

DEVICE NO. 01

ON =

IN

CN1 01 02 03 04 05 06 07 08 09 10

11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 PW PW PW PW

CN2 01 02 03 04 05 06 07 08 09 10

11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 PW PW PW PW

OUT CN3 01 02 03 04 05 06 07 08 09 10

11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 NC

The device number of the selected High Density I/O device appears under

the “HIGH DENSITY I/O” heading. This will be a decimal number from

00 to 63.

This screen displays the inputs and outputs that correspond to the pin

numbers listed for the various connectors on the High Density I/O module.

These are IN CN1 (01 through 37), IN CN2 (01 through 37) and OUT

CN3 (01 through 37).

If an input or output is “ON”, its pin number appears in inverse video.

This is a real time display, and its response is limited only by delays in

screen updates. The following abbreviated symbols may appear:

NC = no connection
PW = power connection

If more than one High Density I/O device is on the I/O Ring, a diagnostics

screen for each of these devices can be displayed. To display a diagnostics

screen for the next high density I/O on the ring, press and hold the

[SHIFT] key and press the [DOWN-ARROW] key.

Pressing the exit softkey (up arrow) at any time displays the Ring I/O

Menu screen.

Advertising