Analog out auxiliary output connector – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 112

Advertising
background image

Section 3A

Primary 9/230 Components

3A-29

ANALOG OUT Auxiliary Output Connector

An auxiliary analog output is provided through the connector labeled

ANALOG OUT. This connector is typically used to command a spindle

drive system with no position feedback. This connector is not capable of

receiving encoder feedback information. Figure 3A.20 shows the location

of ANALOG OUT connector. Table 3A.K lists terminal assignments of

this connector.

Important: For spindle applications, you need to wire the drive to the

analog out connector, and the feedback to a servo connector (J1, J2, or J3).

Figure 3A.20

Analog Out Connector, 3 Plug-type Terminal Block Connections

3

2
1

Table 3A.K

Analog Out Connector Terminal Assignments

Terminal

No.

Signal

Description

Signal Destination

1

Analog Out +

±

10V Analog with no feedback

(typically spindle drive)

2

Analog Out -

Signal Return and chassis ground (typically spindle drive)

3

Shield

connect at control only

Advertising