Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 811

Advertising
background image

Section 15B

Replacement Procedures

15B-55

This ROP interface module resides in the removable operator panel

cabinet. To replace the ROP interface module:

1.

Make sure power to the removable operator panel has been

disconnected.

2.

Open the back cover of the removable operator panel.

3.

Remove the back cover by sliding the cover off its hinge pins. Do

this by firmly pushing the cover to the left while it is open.

4.

Disconnect all cables connected to the ROP module including:

a.

37--pin D--shell removable operator panel interface cable (CN4)

b.

15--pin D--shell video cable (CN19M)

c.

Keyboard interface ribbon cable (CN1)

d.

Monitor power cable (CN2)

5.

Remove the four ROP module mounting screws.

Removable Operator Panel Interface Cable (CN4

has pins)

Video Cable CN19

Keyboard Interface

Ribbon Cable (CN1 )

Monitor power cable (CN2)

Jumper J1 should be between 2/3

6.

Place the jumper installed on jumper J1 across pins 2 and 3.

7.

Installation of the new ROP module is the reverse of steps 1 to 5.

15B.37

Replacing the Removable

Operator Panel (ROP)