Section 15A

Troubleshooting the Control

15A-39

MARKER NOT FOUND

The axis has not yet encountered an encoder marker/null.

MARKER FOUND

The axis has encountered an encoder marker/null since last

reset or power up.

The status of the distance from marker/null is reset whenever there is a loss

of feedback or power to the control.

These are real time displays, response is limited only by delays in screen

updates.

Pressing the exit softkey (up arrow) at any time displays the Main

Diagnostics Menu screen.

When you use the Axis Monitor screen during solid tapping, the position

loop type, gain, and acceleration ramp of the AMPed tapping axis matches

that of the spindle. This may result in a monitored following-error

magnitude for these two axes that is different while in solid-tapping mode.

When they are not in solid tapping mode the monitored following-error

magnitude for these axes is the same.

If you are starting up a 9/440 system, the following screen is available to

help you determine what servo faults, if any , exist on your system prior

to attempting to run the machine. Select the [1394 DRIVE] softkey under

the [MONITOR] section of the [SYSTEM SUPPORT] softkey.

(softkey level 3)

RING

I/O

REMOTE

I/O

FAST

I/O

AXIS

MONTOR

SERIAL

I/O

(softkey level 3)

DATA

SCOPE

SEARCH

MONTOR

1394

DRIVE

15A.7.2

1394 Drives

Diagnostics Screen