Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 808

Advertising
background image

Section 15B

Replacement Procedures

15B-52

Under normal conditions the DC POWER indicator will be illuminated. If

a fuse is blown, the DC POWER indicator will not be illuminated.

One of the following conditions may have caused a blown fuse:

Excessive line voltage
Internal power supply malfunction.

To replace a blown fuse:

1.

Disconnect the cable running from the external power source to the

digital I/O.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the AC distribution

network unless the main AC disconnect switch is open and

locked.

2.

Remove the fuse compartment cover.

3.

Remove the fuse holder; push the handle to the left, then pull

outward.

4.

Remove the fuse from its holder and replace it with a recommended

replacement fuse.

ATTENTION: Use only replacement fuses of the type and

rating specified for the unit. Improper fuse selection may result

in equipment damage.

5.

Place the fuse holder back into its compartment. Push inward until it

locks into place.

6.

Replace the fuse compartment cover.

7.

Restore power. The DC POWER indicator should now be

illuminated.

15B.34

Replacing the Power Fuse

on Digital I/O and Analog I/O

Advertising