Section 4D

Power Distribution and Wiring Guidelines

4D-2

This section discusses the connections of the main power supply and the

operator panel power supply.

Connecting the Main Power Supply to AC Power Source

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

Important: In addition to supplying power to the operator panel power

supply, the main power supply also supplies power to the motherboard,

the CPU board, and the servo module(s) (9/260 and 9/290 only). As

shown in Figure 4D.2, the power cables for these modules originate from

the side of the main power supply (for 9/260 and 9/290).

Refer to Figure 4D.2 while performing these steps:

1.

Locate AC-IN, L1, L2, and PE on terminal block BT04.

2.

Connect the ac power source cable (C02) from the external ac power

source to AC-IN, L1, L2, and PE on BT04.

3.

Connect the chassis ground terminal to the cabinet’s grounding bus bar.

Important: The chassis ground terminal connects to the control chassis

and designated cable shields. Power supply common is AC coupled to

chassis ground. It is the users responsibility to determine if a direct

connection to cabinet ground bus is required.