Section 15B

Replacement Procedures

15B-22

To replace main power supply:

1.

Turn OFF all power to the control.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the ac distribution

network unless the main ac disconnect switch is open and

locked.

2.

Disconnect all cables that are connected to the main power supply

module. Label all cables to simplify installation of the new main

power supply module.

3.

Remove the 4 mounting screws shown in Figure 15B.5 that hold the

main power supply module to the component enclosure.

Figure 15B.5

Locating the Screws on the Main Power Supply

AC POWER

250 V

5.0 A

H

L

H

L

AC
IN

PE

AUX

AC

ON

SW

COM
OFF

SW

4.

Replace the main power supply module with a new one.

5.

Replace and tighten the 4 mounting screws then reconnect all cables

that were disconnected.

15B.7

Replacing the Main Power

Supply on the 9/260 and

9/290