Section 5A

9/440 Resolver--based CNC/Drive System

5A-21

The time delay between the 9/440 resolver--based control receiving the

touch probe trigger and latching the current axis position is negligible.

However, you should be aware of any external delays that may introduce

position “staleness” in the probing operation, especially at high probing

speeds.

It is a good idea to establish an offset for the distance between the actual

location, as sensed by the probe at a very low speed, and the location

sensed by the probe at the intended probing speed. The offset can then be

added or subtracted to any future values obtained through probing. This

helps make sure that if there are any external delays in the trigger signal,

the position staleness shows up as a constant position offset error and is

removed from the measurement (assuming the external delay is

repeatable).

The touch probe interface is intended for use with units that offer 5V dc

compatible solid state relay outputs (see Figure 5A.8). Other

configurations can be supported as long as the user operates within the

published electrical specifications.

The touch probe circuitry resident on the 9/440 resolver--based control

only responds to the trigger probe edge changes. Polarity transition (high

to low or low to high) is selectable through the AMP parameter Probe

Transition. Specify the probe transition in AMP as rising edge or falling

edge. Once the active edge occurs, position data is captured by the

module, and additional occurrences of the trigger signal have no effect

until the probe is re-enabled under program control.

Refer to the 9/Series CNC AMP Reference Manual, publication 8520-6.4,

for more information.

ATTENTION: It is preferred, from a safety standpoint, that the

touch probe relay be closed at rest and open when the touch

probe stylus deflects. Then, if a wire breaks or shorts to ground,

it will appear to the system as a probe fired and the probing

cycle in process will stop commanding motion towards the part.

The user should make every effort towards the fail-safe

operation of the touch probe. Not all vendor’s touch probe

control units conform to this safety consideration.