Section 3A

Primary 9/230 Components

3A-37

Important: Since the adaptive depth probing feature requires one

feedback port to pass probe position data to the control and one feedback

port for normal axis positioning feedback, the adaptive depth feature is not

compatible with the single axis 9/230 processor which only has one

feedback port.

The adaptive depth probe is wired like any A quad B rotary encoder. It is

connected to one of the controls feedback ports. Refer to page 7A-1 for

details on cabling requirements for a feedback device. Table 3A.I lists

specifications for an encoder. These same specifications apply to your

adaptive depth probe.

If you are using the adaptive depth probe to close the position loop

(selected in AMP) the maximum axis speed calculations from Table 3A.I

also apply. Refer to your AMP reference manual for details on other

configuration required to operate using an adaptive depth probe.

In AMP the adaptive depth probe is assigned an axis name. Using the axis

monitor page for that axis (see page 15A-35) you can view the current

following error on the adaptive depth probe and the adaptive depth probe

position relative to zero. The probe is zeroed automatically at power up or

through PAL.

END OF SECTION