5a.5.2 drive power 3 phase – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 278

Advertising
background image

Section 5A

9/440 Resolver--based CNC/Drive System

5A-32

If 24 V power is required for other devices in your machine system, you

can use a 24 V power supply in place of the 24 V transformer as shown in

Figure 5A.16.

Figure 5A.16

Connecting On/Off Power Control Assembly and 24V Power Supply

ON SW

COMMON

OFF SW

AC IN

AUX AC

AC POWER

FUSE

8A/250V

ALLEN--BRADLEY

Customer supplied

24V Power Supply

Output 24 V ac or

24 V dc non-polarized

ON

COM

OFF

E--Stop

COM

RESET

MTB Panel

Incoming Power

85--265 V ac

DC+

INT

COL

W1

W2

U

W

V

PE

9/440 Resolver--based Power Strip

PE

ON/OFF

Control Assembly

BT02

Monochrome or Color

operator panel power

supply

To local cabinet

ground bus

High

Low

Noise suppressor

199-ISMAxx

On Off Relay

Bulletin 100

A30--Nxx

15 AMP

Customer Supplied

Fuses

C

C1

L1

L2

L1

L2

PE

Three--phase power to the 9/440 resolver--based control must be 324-528 V
AC, 50/60 Hz. The drive power is used to supply the drive portion of the

9/440 resolver--based control the voltages necessary to power the axis

modules and the servo motors.

All power connectors on the 9/440 Resolver--based power strip accept

AWG 12 gauge solid wire. Refer to local codes for required wire type and

gauge.

5A.5.2

Drive Power 3 Phase

Advertising