Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 396
![background image](/manuals/580751/396/background.png)
Section 7A
Connecting Components
7A-48
Table 7A.A
Cable and Connector List (continued)
Cable No.
Control
From Module and Connector
Cable Name
To Module and Connector
Cat. No.
C37
9/230,
9/260, and
9/290
1771-HTE Enc. Termination
Panel DRIVE terminal
Analog Servo Amplifier Signal
Cable
Analog Servo Amplifier
Prepared by Customer
or purchase with
AB-Drives
DRIVE
Shield wire, no
connection
at amplifier end.
Analog Drive
Amplifier
(Refer to appendix D
for connection to AB
drives)
Te
rm
Pa
ne
l
DRIVE
RET
SHLD
C37
The connection from the termination panel to the drive
should be as short as possible. We recommend less
than 20 ft.
To Electrical Cabinet PE Bus. 14 Guage.
Repeat for each axis term panel.
11228-I
EXT.
POWER
EXT PWR IN
EXT RET IN
Connector On End of Cable
Cable Type
Connector On End of Cable
Max. Cable Length
none
Belden 9501
Miscellaneous
25 m (82 ft) (measured
from TERM panel)