Section 7A

Connecting Components

7A-48

Table 7A.A

Cable and Connector List (continued)

Cable No.

Control

From Module and Connector

Cable Name

To Module and Connector

Cat. No.

C37

9/230,

9/260, and

9/290

1771-HTE Enc. Termination

Panel DRIVE terminal

Analog Servo Amplifier Signal

Cable

Analog Servo Amplifier

Prepared by Customer

or purchase with

AB-Drives

DRIVE

Shield wire, no

connection

at amplifier end.

Analog Drive

Amplifier

(Refer to appendix D

for connection to AB

drives)

Te

rm

Pa

ne

l

DRIVE

RET

SHLD

C37

The connection from the termination panel to the drive

should be as short as possible. We recommend less

than 20 ft.

To Electrical Cabinet PE Bus. 14 Guage.

Repeat for each axis term panel.

11228-I

EXT.

POWER

EXT PWR IN
EXT RET IN

Connector On End of Cable

Cable Type

Connector On End of Cable

Max. Cable Length

none

Belden 9501

Miscellaneous

25 m (82 ft) (measured

from TERM panel)

Advertising