Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 276

Advertising
background image

Section 5A

9/440 Resolver--based CNC/Drive System

5A-30

Figure 5A.14

On/Off Control Assembly

ON SW

COMMON

OFF SW

AC IN

AUX AC

AC POWER

FUSE

8A/250V

ALLEN--BRADLEY

Incoming AC Power

85--265 Volts AC

To

MTB

panel

ON/OFF switch

Switched AC Out

85--265 Volts AC 8 amp max

PE

L1

L1

L2

L2

Logic power should be wired so that if the 24 V is not available to the

system module, it will open the drive contactors and disable 3 phase drive

power (see Figure 5A.18).