Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 143

Advertising
background image

Section 4A

Primary 9/260 and 9/290 Components

4A-9

The memory for data such as part programs, tool offset/compensation data,

interference zones, and work coordinate offset data is stored in on the CPU

board. In the case of a power failure, there is a super capacitor on the

CPU board that backs up this data for up to 5 days (at 40°C) on systems

without extended program storage. This super capacitor recharges within 1

hour of power turn on if completely discharged. If you want to extend this

backup time, or if you have extended program storage (2 Megabytes) you

install a lithium battery pack (8520-LIBAT) that supports the data for:

9/260 and 9/290 Control and Description:

Time (at 40°C Discharge)

standard

3 years

with extended program storage

1 years

This battery pack is connected to the lithium battery connector (P1) on the

motherboard as shown in Figure 4A.9. Batteries and the battery cable are

included with the battery replacement kit.

Figure 4A.9

Lithium Battery Connector (P1)

Pin Number

Polarity

1
2

--

+

Enclosure

Motherboard

Cable

Lithium Battery Pack

Power Supply

1

2

The lithium battery contains heavy metals and

must be collected separately from other waste.

4A.5

Battery Backup for the 9/260

and 9/290

Advertising