Section 15B

Replacement Procedures

15B-54

To replace the analog I/O:

1.

Disconnect the cable running from the external power source to the

analog I/O.

ATTENTION: To guard against electrical shock hazards, never

make connections or disconnections at the AC distribution

network unless the main AC disconnect switch is open and

locked.

2.

Disconnect the cables running from the external I/O devices to the

analog I/O.

3.

Disconnect the fiber optic cables.

4.

Remove the mounting screws, which are located at each corner of the

analog I/O.

Fuse

5.

Replace the old analog I/O with a new analog I/O.

6.

Replace and tighten the 4 mounting screws then reconnect all cables.

7.

Set the node address to match that of the old analog I/O using the

switch assembly shown below.

This cover unsnaps and folds

down to expose switches

4

3

2

1

O

N

8.

Set the unipolar/bipolar switches to match the settings on the replaced

analog I/O module.

15B.36

Replacing the Analog I/O

Advertising