Section 3B

Power Distribution

3B-8

Connecting the Power Supply to the MTB Panel ON/OFF Switch

Terminal block BT04 terminals ON-SW, COM, and the OFF-SW are

connected to terminal block BT-20 terminals ON, COM, and OFF on the

MTB panel using the ON/OFF signal cable C01. Figure 3B.6 shows

terminal block BT-20 on the MTB panel.

Figure 3B.6

MTB Panel ON/OFF Switch Connection

To Main Power

Supply (BT04)

To Motherboard/

Processor Board

(TB1)

PWR

ON

PWR

COM

PWR

OFF

ESTOP
ESTOP

COM

RESET

BT20

MTB Panel

+12V
GND

OP11

(out)

OP12

(in)

CN51

CN52

I/O ring fault indicator

JPR1

JPR2

Table 3B.B

Operator Panel or Portable Operator Panel Interface Assembly

Power Supply Input Power Specifications

Item

Specifications

Input

Rated Input

115/230V ac --- 50/60Hz

Input Range

90-265V ac --- 47-63Hz

Power Consumption

55 Watts

Fuse

2A/250V

Connection

Terminal Block

Advertising