1 e-stop connections – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 338

Advertising
background image

Section 6

Emergency STOP Design

6-2

Connect the emergency stop circuit to the pluggable E-Stop connector on

as illustrated in Figure 6.1.

Figure 6.1

E-Stop Component Connection

E-Stop

reset

button

E-Stop

button

1 E-Stop

4

5

6

7

Customer

E-Stop

string

E-Stop status

relay contact

connection

On MTB

panel

2 Common

3 Reset

Pluggable E-Stop Connector (TB1 )

E-Stop

status

relay

CR

CR

+

customer supplied fuse

(size to protect K1b contact

and your E-Stop status relay)

8

If your control has, terminal 8, then

connect it to chassis ground. If terminal

8 is not present on your control, then this

type of grounding is not necessary.

Figure 6.2 shows a typical emergency stop circuit. This varies depending

on machine tool configuration, and the devices implemented by the system

installer.

6.1

E-Stop Connections