1 wiring ac power for a ce compliant system, The types of mov that you need are – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 874

Advertising
background image

Section 17

Installing 9/Series for CE Compliance

17-2

If you are integrating a 9/Series that has a final destination within Europe
you must attach a metal oxide varistor (MOV) to all connections that carry

AC power to the system.

If you have this control:

then you need to connect a varistor to:

9/230, 9/260 or 9/290

the incoming AC connection on the power supply

9/440

the incoming AC connection on the ON/OFF module

The types of MOV that you need are:

AC Power Voltage

Manufacturer

Part Number

90-130 V AC

Harris

V130LA20B

130-265V AC

V275LA40B

These devices are available through several vendors, including Newark

Electronics. They can be contacted at:

Country

Phone Number

United Kingdom

(0420) 5433333

France

(1) 30-90-59-90

Germany

02 15 4-9 59 60

USA

312-784-5100

Here is an example of a typical MOV varistor connector on the 9/440

ON/OFF Control Module:

C02

AC power source

AC power source

High

Low

Ground

L1

L2

L1

L2

AC

IN

PE

AUX

AC

ON SW

OFF SW

COMMON

ON/OFF Power Control Module

17.1

Wiring AC Power for a CE

Compliant System

Advertising