1 wiring ac power for a ce compliant system, The types of mov that you need are – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 874

Section 17
Installing 9/Series for CE Compliance
17-2
If you are integrating a 9/Series that has a final destination within Europe
you must attach a metal oxide varistor (MOV) to all connections that carry
AC power to the system.
If you have this control:
then you need to connect a varistor to:
9/230, 9/260 or 9/290
the incoming AC connection on the power supply
9/440
the incoming AC connection on the ON/OFF module
The types of MOV that you need are:
AC Power Voltage
Manufacturer
Part Number
90-130 V AC
Harris
V130LA20B
130-265V AC
V275LA40B
These devices are available through several vendors, including Newark
Electronics. They can be contacted at:
Country
Phone Number
United Kingdom
(0420) 5433333
France
(1) 30-90-59-90
Germany
02 15 4-9 59 60
USA
312-784-5100
Here is an example of a typical MOV varistor connector on the 9/440
ON/OFF Control Module:
C02
AC power source
AC power source
High
Low
Ground
L1
L2
L1
L2
AC
IN
PE
AUX
AC
ON SW
OFF SW
COMMON
ON/OFF Power Control Module
17.1
Wiring AC Power for a CE
Compliant System