Wiring board – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual
Page 266

Wiring Board
P1
+
--
WATCHDOG
XILINX
TB4
J5
J14
TB2 TB3
TB5
SH
LD
G
ND
TP
IN
+5
V
Section 5A
9/440 Resolver--based CNC/Drive System
5A-20
Wiring Board
Drive Interface
P1
+
WATCHDOG
XILINX
TB4
J5
TB5
J14
TB2
RE
T
AN
LG
O
UT
1
SH
LD
RE
T
AN
LG
O
UT
2
SH
LD
TB3
SH
LD
G
ND
TP
IN
+5
V
RIO
2
SH
LD
RIO
1
Battery Backup
Connection
Remote I/O
Plug
Analog Out 1
(spindle 1)
Analog Out 2
(spindle 2)
Touch Probe Connection
F2
Spare
Fuse
F1
Fuse
[ALL FUSES]
[3A/125V]
--
The 9/440 resolver--based system module touch probe connection is made
to connector TB5 on the wiring board. Table 5A.A shows the location of
this connector and lists its terminal assignments.
Table 5A.A
TB5 Connector , 4 Plug-type Terminal Block Connections
Terminal
Description
Signal Destination
+5V
Probe Power
Touch Probe
TP IN
Probe Fired Signal
1
Servo Position Latch
GND
Touch Probe Common
Touch Probe
SHLD
Probe Shield
connect at module only
1
The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as
defined by the AMP parameter PROBE TRANSITION. Refer to your AMP
reference manual for more information.
Important: The touch probe connector supports only +5V probing device
applications.
5A.4.1
Wiring a Touch Probe to the
9/440