Bat/tp (tb1) touch probe connector, P3 5v dc encoder power connector – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 182

Advertising
background image

6

5

4

3

2

1

BA

T/

TP

AX

IS

AN

AL

O

G

BA

T/

TP

RUN

\FL

T

FBF

LT1

FBF

LT2

FBF

LT3

RUN\FLTL

FBFLT1

FBFLT2

FBFLT3

O

UT

11302-I

Section 4B

Connecting the 3-axis Servo Module

4B-36

BAT/TP (TB1) Touch Probe Connector.

The analog servo module receives touch probe feedback through the

connector labeled BAT/TP (TB1). Figure 4B.32 shows the location of the

BAT/TP connector and lists the terminal assignments.

Figure 4B.32

Connector BAT/TP, 6 Plug-type Terminal Block Connections.

Terminal

No.

Signal

Description

Signal Destination

1

Not Used

2

Not Used

3

+5V

Probe Power

Touch Probe

4

PRB_FIRE

Probe Fired Signal

1

Servo Module

5

PE

Touch Probe Common

Touch Probe

6

Shield

Probe Shield

connect at module

only

1

The True level (voltage transition the probe fires) is either “HIGH”or “LOW”as

defined by the AMP parameter PROBE TRANSITION.

Refer to the 9/Series

CNC 9/230, 9/260, and 9/290 AMP Reference Manual, publication

8520-6.4, for more information.

Important: The touch probe connector supports only +5V probing device

applications.

P3 5V dc Encoder Power Connector

The analog servo module receives +5V dc power directly from the main

power supply through connector P3. This +5V dc power is used only for

powering the encoder. If the EXT Power connection on the encoder

termination panel is used or if the 15V dc encoder power is used the

connection to P3 is not needed. Figure 4B.33 shows an end view of

connector P3 and lists the pin assignments. For details on this connection

refer to the section on the main power supply connections on page 4D-4.