15a.4.5 mtb panel i/o diagnostics screen – Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 732

Advertising
background image

Section 15A

Troubleshooting The Control

15A-22

If a MTB Panel I/O device is selected on the Ring I/O screen and the

{DISPLY} softkey is pressed, the MTB I/O Diagnostics screen appears.

Figure 15A.8 is an example of this screen.

Figure 15A.8

MTB Panel I/O Diagnostics Screen

MTB PANEL I/O

SETUP MODE

DEVICE NO. 01

ON =

IN

01 PW 03 PW 05 PW 07 PW 09 PW
11 PW 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
31 32 33 34 35 36 37 38 39 40
41 42 43 44 45 46 47 48 49 50

OUT

01 GD 03 GD 05 GD 07 GD 09 GD
11 GD 13 GD 15 GD 17 18 19 20
21 22 23 24 25 26

The device number of the selected MTB Panel I/O device appears under

the “MTB PANEL I/O” heading. This will be a decimal number from 00

to 03.

This screen displays the input and output pin assignments that correspond

to the input and output connectors on the MTB Panel I/O module.

If an input or output pin is “ON”, it appears in inverse video. This is a real

time display, and its response is limited only by delays in screen updates.

The following abbreviated symbols may appear:

PW = power connection
GD = ground connection

If more than one MTB Panel I/O device is on the I/O Ring, a diagnostics

screen for each of these devices can be displayed. To display a diagnostics

screen for the next MTB panel I/O device on the ring, press and hold the

[SHIFT] key and press the [DOWN-ARROW] key.
Pressing the exit softkey (up arrow) at any time displays the Ring I/O

Menu screen.