The control transmits data to the peripheral in the following sequence. The

numbers correspond to those in Figure 8.11.

1.

The control turns the CS and the DM signals ON to notify the

peripheral that there is data to be transmitted.

2.

The peripheral turns the RS signal ON to notify the control that it is

ready to receive data.

3.

The control begins data transmission to the peripheral.

4.

If the peripheral buffer cannot accept the data, the peripheral turns the

RS signal OFF to notify the control to stop data transmission.

5.

The control, upon recognizing the RS signal has been turned OFF,

stops transmitting data within two characters.

6.

The peripheral turns the RS signal ON when it can receive data again.

7.

The control, upon recognizing the RS signal has been turned ON,

begins data transmission .

8.

After transmitting all data to the peripheral, the control turns the CS

and DM signals OFF to notify the peripheral that all data has been

transmitted.

9.

The peripheral turns the RS signal OFF.

Level II protocol is used for the communication between the control and a

peripheral (tape reader/puncher) or a computer. Level II protocol differs

from Level I protocol in that data transmission/reception is controlled by

the control codes ( DC1, DC2, DC3, DC4, EOT, DLE ). The functions of

these control codes are shown in Table 8.E.

Devices where the protocol is labeled LEVEL 2* implement a slightly

modified version of the protocol. This serves to better match the specific

Level 2 device. The device type GENERIC LEVEL 2 implements the full

protocol as it is described here.

The 9/Series controls send and receive program data using the data format

appropriated for punched tape. This means all ASCII characters have even

parity in the eight bit position. EIA characters have their own parity

format which is recognized by the control. Characters which do not have

the proper parity are not stored in the control. In addition, lower case

ASCII data sent to the control is converted into upper case when stored.

RS-491 Level 2 control characters do not have eighth bit parity. The

control characters are used for device control only.

8.7.2

RS-491 Level II Protocol