Section 5A

9/440 Resolver--based CNC/Drive System

5A-23

To avoid misfires use the threshold values from the above table to

determine the necessary signal voltage for steady state operation (probe not

fired). For probes configured to fire on the falling edge the steady state

voltage must remain above 3.06 volts. For probes configured to fire on the

rising edge the steady state voltage must remain below 2.18 volts.

Wiring a Probe for Rising Edge Configurations

Typical wiring of a simple contactor type touch probe configured to fire on

the rising edge of the probe signal, requires the addition of a 1000 ohm pull

down resistor. Figure 5A.9 shows a typical wiring diagram compatible

with most probe designs configured to trigger on the rising edge of the

probes signal.

Figure 5A.9

Typical Wiring of a Touch Probe Configured for Rising Edge Trigger

9/440 Resolver--based Control

Wiring Board

470 ohm

5V common

1000 ohm

+5 V dc

1000 ohm

pull down resistor

(customer supplied)

Probe Contact

to encoder interface

4
3
2
1

Advertising