I/O Interface

Section 10A

10A-15

Important: When an inductive load (a relay, for example) is directly

connected to the output circuit, connect a noise suppressor in the circuit,

parallel with the load.

Figure 10A.9

Output Device Requiring a Noise Suppressor

Fiber

optics

MTB Panel I/O Module

MTB Panel

Operator Panel

Noise

suppressor

Load

dc power

supply

11315-I

Converted

from optical
to electrical
signal

+12V

Common

Output

Common

Table 10A.I lists the connectors used to make the fiber optic connections to

the I/O ring. Each module connected to the system I/O ring has an optical

transmitter and receiver. Fiber optic cables connect transmitters to

receivers to form the I/O ring. Refer to Appendix A for additional

information on fiber optic cables and connectors.

Table 10A.I

Push-Button MTB Panel I/O Module Fiber Optic Connectors

Connector on Rotary MTB

Panel I/O Module

Connected To

Remark

OP11 (RED)

Receiver on next module in I/O ring

Output

OP12 (BLacK)

Transmitter on previous module in I/O ring

Input

10A.2.3

Push-Button MTB Panel I/O

Module Fiber Optic

Connection