Rockwell Automation 8520 9/Series CNC Integration Maintenance Manual Documentation Set User Manual

Page 98

Advertising
background image

Section 3A

Primary 9/230 Components

3A-15

Important: TB3 (labeled ANALOG OUT) should only be used for drive

applications that do not require a feedback device. If a feedback is

required, the output signal to the drive and its corresponding encoder

feedback should be wired through one of the axis connectors J3, J2, or J1.

A drive application with feedback would typically not use the connector

TB3.

Figure 3A.11

Analog Out Connector, 3 Plug-type Terminal Block Connections

1 2 3

Table 3A.G

Analog Out Connector Terminal Assignments

Terminal

No.

Signal

Description

Signal Destination

1

Analog Out +

±

10V Analog with no feedback

(typically spindle drive)

2

Analog Out -

Signal Return and chassis ground (typically spindle drive)

3

Shield

connect at control only

Advertising