background image

Editing Ladder Logic

6-31

§

Use the

[Backspace]

key to delete the old address. (You can also press

[Esc]

to quickly clear the entire address.) Type the new address. Press

[Enter]

. If

you change a base address, all of the relative addresses associated with that

address (below the base, up to the next base) also change.

4.

When you have finished editing the index, press

[Esc]

to return to the Import

Configuration menu.

Freeing the Scrap Buffer

If you are running low on memory, you may want to free the memory in the scrap

buffer, particularly if you have copied a large set of rungs to the buffer. There are two

ways to do this. One is to exit from the Offline Editor. The other is via the block

menu.

To free the scrap buffer while remaining in the editor:

1.

Select

[F7]

Free

while in the block editing mode. The following warning message

appears.

2.

Select an option from the menu

§

Press

[F1]

to abort the operation, retaining the scrap buffer.

§

Press

[F2]

to delete the contents of the scrap buffer.

§

Press

[F3]

to save the contents of the buffer to a library file before deleting it.

The Export Configuration screen will appear. Refer to

Saving a Block of

Rungs

on page

6-24

for details on saving the buffer.

Command Portal keys
for this function:

.EKF