MicroLogix 1000 and PLC-500 A.I. Series Software Reference

19-6

Processor Status

The processor status screen displays the contents of the processor status file, S2. This

includes fault information that can be useful for troubleshooting.

To display the processor status screen:

1.

From the top level in the ladder editor, press

[F8]

Display

. The function keys at

the bottom of the screen change to show the display options.

2.

Press

[F2]

Prcstat

. The processor status screen appears.

SLC 5/02 and higher processors have more processor status information than can be

displayed on a single screen. Use the

[PgUp]

and

[PgDn]

keys to page through the

status display screens. A description of the bit or word under the cursor is displayed

near the bottom of the screen.

For more information on the Processor Status Screen, refer to

Processor Status

Configuration

in

Chapter 3 - Configuring the SLC 500 CPU and I/O Modules

. For

more information on the status file, refer to

Appendix A - Programming Reference for

Packaged Controllers

in the

Instruction Set Reference

.

Command Portal keys
for this function:

.DP

Note: Fault bits cleared
by

[F4]

Clrfalt

.