MicroLogix 1000 and PLC-500 A.I. Series Software Reference

14-8

Export Rung Descriptions and Page Titles

Each rung description and page title is exported as a single record. Each record

contains three fields:

1.

Address

. Variable length. Depending on the attach mode, this field will contain

either data table addresses or a pseudo address representing the rung number. The

pseudo address for the rung number will be in the format “RUNGxxx-yyyy”, where

“xxx” is the ladder file number (002-255) and “yyyy” is the rung number within

that ladder file.

2.

Page Title

. 80 Characters. This field contains the text of the page title. If no

page title is associated with the address, a pair of double quote marks will be

present to mark the position. Because double quotes delimit the page title record,

any double quotes used in the page title will be changed to single quotes on export.

3.

Rung Description

. Up to 64K (approximately 16 pages). This field contains the

text of the rung description associated with the address.

The example below shows two records. The first record contains information in all

three fields. The second record contains three fields, but the Page Title field is empty.

“C5:0”,“COUNTERS TO TOTAL PIECES”,“COUNTER TO TOTAL STATION 1 PIECES”