MicroLogix 1000 and PLC-500 A.I. Series Software Reference

7-6

Changing Remote Modes

PLC-500 A.I. can perform remote processor mode changes. Functions such as

[F6]

Utility

,

[F2]

Load

(in the online editor) and the download function, include a mode

change option when necessary. PLC-500 A.I. will ask you to confirm the mode change

before sending the codes to change the mode.

The Mode functions include keys to move between the Online and Offline modes and

keys to control the emulator (if available: the Processor Emulation module is a

separately purchased option) from the Offline editor.

!

When you switch the SLC 500 processor to the Run mode, outputs energize and de-

energize based on the ladder logic in the processor. If forces are present and

enabled, they take effect immediately. Use extreme caution when changing SLC 500

processor modes.

To change the processor mode:

1.

From the top level of the ladder editor, press

[F9]

Mode

. The menu bar displays

the Mode options. The choices will be different depending on whether you are in

Offline or Online editing.

From Offline:

From Online:

2.

Press the function key corresponding to the mode you wish to use. PLC-500 A.I.

will ask you to confirm that you wish to change modes before switching to the

selected mode. The status bar will change to indicate the current mode. The tables

below describe the Mode options.