Troubleshooting and Diagnostics
19-31
To set up a non-sequential rung list:
1.
From the top level in the ladder editor, press
[F6]
Utility
.
2.
Press
[F7]
Rnglist
. The system prompts you for the list of rungs.
3.
Type the file and rung number for each of the rungs you want to display, separated
by spaces. You can omit the file number for rungs in the current file. For
instance, if you are in file 2 and want to display rungs 2:2, 2:17, 2:127, 3:5, 4:8,
and 7:9 type
2 17 127 3:5 4:8 7:9
.
4.
Press
[Enter]
to accept and display the list.
To cancel a list (or display a new one):
1.
Press
[F6]
Utility
,
[F7]
Rnglist
again.
2.
At the prompt, press
[F1]
Yes
to cancel the list.
3.
You will be prompted for another list. Either enter a new list of rungs, or press