MicroLogix 1000 and PLC-500 A.I. Series Software Reference

16-18

Configuring Channel 1

You can change the configuration for Channel 1. It is generally simpler to do this

while online with the processor, however, it is possible to make changes to channel

configurations offline and download the new configurations as part of the ladder logic

project.

To configure Channel 1:

1.

Go online with the processor.

2.

Select

[F8]

Display

.

3.

Select

[F7]

chancFg

. This displays the channel configuration screen. (The screen

shown here is for a SLC 5/04 processor.)

4.

Use the arrow keys to move the highlight bar to the

System Mode Driver

field for

Channel 1.

5.

If you are using a SLC 5/03 processor, you can set the driver to

DH-485 Master

or

Shutdown

. If you are using a SLC 5/04 processor, you can set the driver to

DH+

or

Shutdown

. If the channel is

Shutdown

, press

[F9]

Select

to toggle the setting

back to

DH-485 Master

or

DH+

.